Home > What Is > What Is Soft Media Error

What Is Soft Media Error

Confirm and manage identities. So far no Harm! Solution AceSearch [Clariion]Clariion SP Error Code Explained - Part Two- SOFT CODES 20 November 2008 Hits: 6834 Print Email SOFT CODESThese codes are also known as threshold codes.0x801, Soft SCSI Error: Try it out!DownloadWhy Advertise on Mikes.eu Mikes.eu traffic varies depending on the post.

Default Passwords What is EMC's CAVA / Common Event Enabler? Locate partners—or learn about becoming one.Find EMC PartnersEMC Business Partner ProgramBecome an EMC ResellerPartner CommunityPartner PortalRSA PartnersDell PartnerDirectContact UsPartner with EMC today.Live ChatContact SalesCall 1-866-438-3622Call 1-866-438-3622Company InformationKeep up with the news, RSS feed Search for: Top Posts & Pages Useful Brocade FOS CLI Commands Useful Celerra / VNX File Commands SAN Performance Metrics What is VPLEX? You could have the disk replaced for this.I'd open a SR if in doubt. http://www.mikes.eu/index.php/how-to/158-emc-soft-media-error.html

For status code 9, the drive should be replaced. The SP sent a command to the drive, and the drive did not respond in time.0x07 - Select timeout. We have been ranked in the top 5 of Favorite Independent Blogger and one of the most visited website. Note: 801 and 901 events are not strictly confined to being a disk-related problem.

The SP sent an 'I want to talk to this drive now' message, and the drive did not respond in time.0x2A - Bad transfer count. After some detective work it's not that bad. Look at the extended status (described in the Fix statement) for the affected drive to determine the cause of the event.   Action required: If 6A0/820 and 920 is received - Event codes included 0x6a0, 0x820, and 0x801 with descriptions of disk soft media error, soft scsi bus error, and soft media error.  My suggestion is to filter only on description, and

The drive transferred valid data to the SP. 0x22 - The drive encountered an error reading data, but was able to recover using its internal ECC mechanisms. But when you get more that just two (significant 20 - 100 or more) alerts on the disk. Time to be proactive… I opened a case with EMC support, and sent them screenshots of the SP event logs, and SPCollects from both SPA and SPB, and noted that https://thesanguy.com/2011/06/03/reporting-on-soft-media-errors/ Tuesday, 01 November 2016 HomeDisclaimerAbout me Twitter Facebook LinkedIn RSS Google+ @BBakkenist Ow?

The drive transferred valid data to the SP.0x22 - The drive encountered an error reading data, but was able to recover using its internal ECC mechanisms. Please register now for a free copy of this e-book.Download EMC Elect 2016  EMC Elect represents an unprecedented opportunity for members to receive exclusive access, privileges, and status in appreciation for Reviewing the disks within the navisphere GUI showed that no disks were faulted, the dashboard showed no errors, and the hot spare was not in use, meaning the array did not We have been ranked in the top 5 of Favorite Independent Blogger and one of the most visited website.

The sector was successfully read. 20 - Hard Media Error. https://community.aveksa.com/thread/164826?start=0&tstart=0 The system returned with a 0x05 code which means A bad block was detected and remapped on the drive. I want to set it back to 0 now that the disk has been replaced. Report Abuse Like Show 0 Likes (0) 3.

Please replace this disk.   Environment: CLARiiON FC-series CLARiiON CX-series CLARiiON CX3-series   Description of events: 6A0/820 - Soft Media Error. You can not post a blank message. The drive's predictive failure analysis has determined that the drive is likely to fail soon. Try it out!DownloadWhy Advertise on Mikes.eu Mikes.eu traffic varies depending on the post.

Fill in your details below or click an icon to log in: Email (required) (Address never made public) Name (required) Website You are commenting using your WordPress.com account. (LogOut/Change) You are Posted in How to TweetWhat is the meaning of CLARiiON soft and hard SCSI and media errors with extended status codes? The next version of ATA firmware (1.67) will fix the problem. Read more Everything you need and nothing you don’t.

These extended status codes indicate a problem with the backend loop. Complete list of event logs thrown as part of the proactive copy completion: 0x6b0, 0x712d4601, 0x906, 0x7a7, 0x608, 0x6a1, 0x602, 0x7a5, 0x6a8, 0x712789a0, 0x67b, 0x67c, 0x603, 0x602, 0x712d0508, 0x604, 0x712d0507, 0x2580, See also 323440x19 - Predictive Failure Analysis fault threshold reached.0x21 - The drive encountered an error reading data, but was able to recover by re-reading the sector.

extremesanity.com Obscure solutions to obscure problems Home Home > EMC VNX > Proactive copy to hot spare on EMC VNX array Proactive copy to hot spare on EMC VNX array March

Sometimes seen during a FLARE upgrade that involves updating the FRUmon code. 0x11 - This is a benign soft under run error seen on ATA drives with FLARE Release 14 (02.07) The system returned with a 0x05 code which means A bad block was detected and remapped on the drive. These typically indicate that there is a larger issue and/or that the predictive failure algorithms have found issues.For now, what you are seeing is probably nothing, just watch the error counts To run a report that pulls only soft media errors from the SP log, put the following in a windows command file: naviseccli -h  getlog >textfile.txt for /f "tokens=1,2,3,4,5,6,7,8,9,10,11,12,13,14" %%i

I am looking what is 6a0 type error. Although soft errros will not cause the data not to be written, a lot of these are suspicious. Checking progress of the proactive copy Now to check progress of the copy… First I tried looking at the disks in the GUI The disk state is listed as "Copying The drive transferred valid data to the SP. 0x22 - The drive encountered an error reading data, but was able to recover using its internal ECC mechanisms.

Incoming Links Erro de mídia soft do disco 6a0 Re: Error por defectos en los medios de disco 6a0 Dell Technologies© 2016 EMC Corporation. So far no Harm! The error indicates that the retry attempts failed. 803 - Recommend Disk Replacement. The drive transferred valid data to the SP. 0x3A - Following a corrected error, the drive remapped the marginal sector. 0x3B - The drive was unable to remap a marginal sector.

The SP sent a command to the drive, and the drive did not respond in time. 0x07 - Select timeout. Re: Soft Media Error? コミュニティマネージャ Nov 1, 2012 1:30 AM (コミュニティマネージャ への返信) Soft Media Errorは不良ブロックを見つけたストレージが、そのブロックに対してDrive ECC、もしくはRAIDの機能を利用して正しい情報を(再度)書き込んで修復、もしくは当該ブロックが利用出来ないと判断した場合にはスペアセクター(ブロック)に書き込んで修復したことを報告するものです。※エラーと出力されますが修復済みを意味していますしたがって、単発のエラーであれば無視をして頂いて問題ないのですが、頻発するようでしたらEMCカスタマーサポートセンターへ状況確認の依頼を行うことをお勧めします。(その際には調査のためにSPCollectログを提供する必要があります。) 不正使用の報告 いいね お気に入り1件を表示 (1) 2. This is normal. Look at the extended status (described in the Fix statement) for the affected drive to determine the cause of the event.   Action required: If 6A0/820 and 920 is received -

Regards,Muneer. 11614Views Tags: none (add) support Content tagged with support , clariion Content tagged with clariion Categories: CX-Series 1. We are in the same boat where it shows 100% even though we know that is not the case. Where you can end up getting to an out of normal state is when you might receive 25-100+ of these on a single drive in a close time proximity. Report Abuse Like Show 0 Likes (0) Go to original post Actions More Like This Retrieving data ...

Received alert navisphrer Event, Number 820, Support team says, this is 6a0 Disk soft media error [Recovered error (on-drive ECC)] can ignore.??? The extended error code can, however tell you where the root cause would have occured for various types of soft media errors. EMC MOBILE is the essential tool for those of us who live EMC. Re: Soft Media Errorとは? c3po Feb 8, 2016 8:46 PM (コミュニティマネージャ への返信) 0x820 Soft Media Errorは、修復したことを報告するものであるため通常問題無く静観頂けるアラートです。またログされた理由は、KB26708に記載されている、下記のExtended statusにて確認可能です:Extended status codes can be found in the Storage Processor event logs.0x1c - Bad Sense

Update: I came across a new EMC article today that may have a command that will work to gauge progress better.  I have not attempted it myself yet. HOMEHOW TOWHAT ISCERTIFICATION EMCDetailed information and get Certified Big Data OverviewAppSync Configuration and Management Overview VMwareDetailed information and get Certified VCP 5 CertificationVMware vSphere: What’s New [V 5.1]Business Continuity and Disaster The problem may be with the reporting drive, another drive on the loop, an LCC or cable, or the SP. At this point I gave the EMC CE a call and scheduled replacement of the drive.  Once the replacement drive is in place, the array should copy the information on the